Over Pressurisation System (OPS) Skids
Available in: 10-10,000 Psi & 10,000-20.000 Psi
Available in: AZ-1-19, 36, 58, 107, 140, 187, 275, 425
Equipment Specifications
- Air Inlet: 100 psi air supply operate the skids own system
- Shut down connection: To tie into the shut down system on a diesel or air driven pump
- Calibration port inlet: Supply prom an external source to set up the skid to its desired switching pressure when in calibration mode
- Sensing port inlet: To supply pressure from the system being pressurised, when in normal mode
- Relief valve outlet: The main skid protecting valve. Prevents the skid from being over pressurised. The outlet is designed so if noxious substance is being pressurised, it can be piped out safely.
- Air supply vent: Used to vent the skid and any associated supply air lines
- Chart recorder outlet: To Keep a permanent record of the pressure test
- Gas vent: Can be used to vent the system being pressurised
- 2 x Gauge Ports